Why the same flange can look out of tolerance in automet HORIZ/VERT yet within tolerance as a PolyWorks 3D angle. Compare both reports side by side on an interactive 3D model.
Using older 3D CMM measuring machines is a temporary solution to save costs and address measurement and quality control issues in small and medium-sized enterprises with limited capital. Therefore, Renishaw has researched and launched measuring head systems that significantly upgrade and improve measurement capabilities using only PH10 and PH20 measuring heads.
Renishaw probes and sensors are the core foundation in coordinate measurement (CMM) and machine tool measurement (CNC) technology. These devices act as the first link directly connecting to the workpiece, allowing the machine to collect X, Y, and Z coordinate data to calculate the dimensions, shape, and position of geometric features.
Why the same flange can look out of tolerance in automet HORIZ/VERT yet within tolerance as a PolyWorks 3D angle. Compare both reports side by side on an interactive 3D model.
When a pipe spool or bent tube is inspected, each flange axis is compared with its design axis. Two common software packages describe the same result in different ways, and the numbers do not always look alike. The interactive 3D model below shows the same flange, with the same design axis and the same measured axis, reported both ways.
The two descriptions are consistent: cosθ = cosV₁·cosV₂ + sinV₁·sinV₂·cos(H₂ − H₁). The key point is that the HORIZ error is weighted by sin VERT. On a horizontal pipe, HORIZ and VERT errors translate almost directly into tilt. On a near-vertical pipe, a large HORIZ error can mean a very small real tilt in space, so a flange that looks out of tolerance in HORIZ may be well within a 3D angle tolerance. Agreeing on which quantity the tolerance applies to avoids false rejects and disputes between supplier and customer.
Drag either model to rotate, scroll or pinch to zoom. Use the presets Horizontal pipe, Inclined pipe and Near-vertical pipe, and adjust the HORIZ and VERT errors (actual minus design) to see both reports update side by side.
Need help setting up pipe and flange inspection with PolyWorks or a portable CMM? Contact V-PROUD for a consultation.
(84) 896 555 247